EXODUS

Technology
The revolutionary exosome isolation technique, powered by ultrasonic nano-filtration technology, offers significant advantages over traditional membrane separation methods. This innovative approach combines negative pressure oscillation (NPO) with double-coupled ultrasonic harmonic oscillation (HO). Together, these mechanisms work synergistically within the nano-filtration device to efficiently and rapidly remove impurities such as free nucleic acids and proteins, enabling the extraction of ultra-pure exosomes. The choice of exosome enrichment and purification consumables is tailored to match the specific sample volume needs, sample type, and intended application.

Isolation Principles
EXODUS has been developed using a dual-membrane nanofiltration system that integrates periodic negative pressure oscillation (NPO) and double-coupled ultrasonic harmonic oscillations (HO). EXODUS can rapidly remove free nucleic acid and protein impurities from the sample, resulting in the efficient purification and enrichment of exosomes. The exosomes are precisely intercepted by a nanoporous membrane, allowing for a highly targeted isolation process.

EXODUS isolation principle for EV subtypes
EXODUS can rapidly remove free nucleic acid and protein impurities from the sample, resulting in the efficient purification and enrichment of exosomes. The exosomes are precisely intercepted by a nanoporous membrane, allowing for a highly targeted isolation process. EXODUS has great potential to revolutionize exosome isolation and drive new discoveries in biomedical research and translation.

Various sample types:

Plasma

Plasma

Urine-300x300

Urine

Saliva-300x300

Salvia

Cerebrospinal-fluid-300x300

Cerebrospinal Fluid

Tears

Tears

Aqueous humor

Aqueous Humor

Synovial-fluid-300x300

Synovial Fluid

Tissue-300x300

Tissue

Cell culture medium

Cell Culture Medium

Bacterial culture medium

Bacterial Culture Medium

Cell-derived-vesicle-300x300

Cell Derived Versicle

Plant

Plant

EXODUS H-600

T-2600

EXODUS T-2800

Specifications

EXODUS H-600

EXODUS T-2800

Sample volumes

10 μL – 250 mL

1-10 L

Processing speed

200 mL/h

1000-2000 mL/h

Dimension

535 x 510 x 475 mm

820 mm x 500 mm x 685 mm

Weight

40 kg (88 lbs)

90 kg ( ≤200lbs )

Isolation principles

Combination of the negative pressure oscillations (NPO) and double coupled
harmonic oscillations (HO) on nanoporous membrane

Sample types

Plasma, urine, saliva, cerebrospinal fluid, tears, aqueous humor, synovial
fluid, tissue, cell culture medium, bacterial culture medium, cell-derived
vesicle, plant, ect.

Temperature Control 

Sample position, buffer position, and exosome recovery station, with a controlled temperature range of 2-8°C

Specifications

EXODUS H-600

Sample volumes

10 μL – 250 mL

Processing speed

200 mL/h

Dimension

535 x 510 x 475 mm

Weight

40 kg (88 lbs)

Isolation principles

Combination of the negative pressure oscillations (NPO) and double coupled
harmonic oscillations (HO) on nanoporous membrane

Sample types

Plasma, urine, saliva, cerebrospinal fluid, tears, aqueous humor, synovial
fluid, tissue, cell culture medium, bacterial culture medium, cell-derived
vesicle, plant, ect.

Temperature Control 

Sample position, buffer position, and exosome recovery station, with a controlled temperature range of 2-8°C

Specifications

EXODUS T-2800

Sample volumes

1-10 L

Processing speed

1000-2000 mL/h

Dimension

820 mm x 500 mm x 685 mm

Weight

90 kg ( ≤200lbs )

Isolation principles

Combination of the negative pressure oscillations (NPO) and double coupled
harmonic oscillations (HO) on nanoporous membrane

Sample types

Plasma, urine, saliva, cerebrospinal fluid, tears, aqueous humor, synovial
fluid, tissue, cell culture medium, bacterial culture medium, cell-derived
vesicle, plant, ect.

Temperature Control 

Sample position, buffer position, and exosome recovery station, with a controlled temperature range of 2-8°C